CINRIWA AIR FILTRATION

HEPA & ULPA Filters for Clean-Air Systems

Explore mini-pleat, gel-seal and separator filter constructions for clean-air equipment and air-handling systems. Select the required filtration class, then match the dimensions, sealing interface, operating airflow and applicable test documentation to your installation.

Gel Seal HEPA / ULPA FiltersDeep-pleat Separator HEPA FiltersMini-pleat HEPA / ULPA Filters
PRODUCT RANGE

Explore Our Filter Constructions

Compare the available filter constructions below. Filtration classes, frame materials, dimensions and sealing options vary by model.

Mini-pleat HEPA / ULPA Filters

Mini-pleat HEPA / ULPA Filters

Mini-pleat microglass filter packs with model-specific frame depths and gasket configurations. Match the selected class and sealing face to your clean-air equipment.

Build
Mini-pleat microglass
Seal / fit
Polyurethane gasket
View Details →
Gel Seal HEPA / ULPA Filters

Gel Seal HEPA / ULPA Filters

Mini-pleat filters with a gel channel for compatible knife-edge housings. Confirm the channel position, interface dimensions and insertion requirements.

Build
Mini-pleat microglass
Seal / fit
Gel channel / knife-edge interface
View Details →
Deep-pleat Separator HEPA Filters

Deep-pleat Separator HEPA Filters

Microglass media with corrugated aluminium separators. Compare the available depths, frame materials and gasket arrangements for your housing.

Build
Deep pleats / aluminium separators
Seal / fit
Gasket; configuration by model
View Details →
Paper Separator HEPA Filters

Paper Separator HEPA Filters

Microglass filter media with paper separators in a galvanized steel frame. Select the dimensions and flange arrangement required by the installation.

Build
Paper separators / microglass media
Seal / fit
Flange and sealing arrangement to confirm
View Details →
High-temperature Separator HEPA Filters
TEMPERATURE-SPECIFIC APPLICATIONS

High-temperature Separator HEPA Filters

A separator construction for temperature-specific applications. Confirm the complete frame, seal and filter-pack configuration against the operating temperature profile.

Build
Aluminium separators / microglass media
Seal / fit
Temperature-specific configuration
View Details →
COMPARE & SELECT

Which Filter Construction Fits Your Installation?

Start with the required filtration class and the existing housing. Compare the sealing method, available depth, operating airflow and pressure allowance before choosing a replacement or a new configuration.

ConstructionSelection focusConfirm before ordering
Mini-pleat HEPA / ULPA FiltersFrame depth and gasket contactClass, actual dimensions, gasket position, airflow and pressure drop.
Gel Seal HEPA / ULPA FiltersGel channel and housing knife edgeTop or side gel, channel geometry, knife-edge position and insertion requirements.
Deep-pleat Separator HEPA FiltersAvailable depth and frame configurationFrame material, dimensions, gasket, protective grids and service access.
Paper Separator HEPA FiltersHousing dimensions and flange fitActual depth, flange arrangement and housing sealing interface.
High-temperature Separator HEPA FiltersTemperature suitability of the complete assemblyContinuous and peak temperatures, duration, frame, gasket and installation requirements.

Match the housing interface

The same outside dimensions do not make gel, gasket and flange interfaces interchangeable. Check the actual contact and retaining arrangement.

Compare at operating airflow

Read pressure drop together with filter size, class and airflow. Confirm that the equipment has the pressure allowance required for operation.

Confirm the complete assembly

Media, frame, seal and installation components must all suit the operating conditions. This is particularly important for heated-air applications.

CLASSIFICATION & DOCUMENTATION

Understand Filter Classes & Test Documentation

Read a classification together with its test standard and the selected model. The EN 1822 groups below explain the terminology; they are not a list of all classes available from CINRIWA.

EPAE10–E12

A classification group within EN 1822. Availability of an EPA-class model must be confirmed for your enquiry.

HEPAH13–H14

Confirm the selected model's class, applicable test basis and required documentation.

ULPAU15–U17

A separate classification group. A series name or media type alone does not establish the class of a supplied filter.

What does MPPS mean?

MPPS means the most penetrating particle size under the test conditions. Read a filter's efficiency together with its classification standard and test conditions rather than relying on a percentage alone.

Filter classification

Specify the required class and applicable standard. Confirm that the exact model is supported by the relevant product data.

Factory documentation

State the records, test results and identification or traceability you require. Confirm which documents can be supplied for the selected configuration before ordering.

Installed-system testing

Define the site acceptance and leak-testing requirements for the installed filter and sealing interface. Factory testing and installed-system testing address different conditions.

A filter classification does not establish the cleanliness classification of a complete room. System design, installation and project-specific verification remain part of the overall requirement.

Classification reference: EPA / HEPA / ULPA classification overview. This reference explains terminology and does not certify CINRIWA products.

DIMENSIONS & INSTALLATION

Dimensions, Seals & Housing Compatibility

Provide the actual outside dimensions and the housing interface details. Frame depth, flange dimensions, gasket position and gel-channel geometry should be identified separately.

Outside frame dimensions

Front view: width and heightMeasure width from the outside left edge to the outside right edge, and height from the outside top edge to the outside bottom edge. Width (W)Height (H) Side view: depthMeasure depth across the narrow side of the frame, from its front face to its back face. The drawing is illustrative and not to scale. Depth (D)

Width × Height × Depth (mm) · Outside edges · Not to scale

Gel-channel interface

Illustrative cross-section of a housing knife edge entering a gel channelKnife edgeGelInterface illustration only — not to scale

Confirm the actual channel, knife-edge position and insertion requirements against the housing drawing.

Gasket & flange constructions

Measure outside width, height and overall depth. Identify the gasket contact face, retaining arrangement and any flange dimensions separately. Include installation and removal clearances.

Gel-seal constructions

Specify top-gel or side-gel configuration where offered. Provide the channel dimensions and matching housing knife-edge details. The same outside size alone does not establish compatibility.

Operating conditions

Provide the required class, airflow and allowable pressure drop, along with temperature, humidity and any liquid exposure. For heated-air service, include continuous and peak temperatures and duration.

Send a photo or drawing

Include the existing filter label, sealing interface, housing drawing and quantity. Custom sizes and configurations require confirmation for the selected model.

Explore Custom Filter Solutions →

APPLICATIONS

Applications in Clean-Air Systems

Select the filtration task and installation interface against the complete system requirements.

Cleanroom Terminal Filtration

Filter options for terminal housings in clean-air systems. Select the class, airflow and sealing arrangement against the project specification.

Explore Electronics Applications →

FFUs & Local Clean-Air Equipment

Match filter depth, pressure drop and the gasket or gel interface to the equipment design. Confirm the exact configuration for new equipment or replacement filters.

View Gel-Seal Filters →

Air-Handling & Equipment Replacement

Review the existing housing, filter label, sealing face and maintenance access before selecting a replacement configuration.

Read the Selection Guide →

Temperature-Specific Processes

Review the complete filter, frame and seal configuration against the operating temperature profile. A separator construction alone does not establish high-temperature suitability. Review the temperature-specific series →

COMMON QUESTIONS

EPA, HEPA & ULPA Filter Questions

Answers to common questions about classification, sealing, replacement and documentation.

What is the difference between EPA, HEPA and ULPA filters?

These are classification groups within EN 1822: E10–E12, H13–H14 and U15–U17 respectively. Select the exact class against your specification and confirm model availability and applicable test data. The category name does not mean every class is available in every construction.

Does a higher filter class always mean a better choice?

The filter must meet the system requirement while remaining compatible with the equipment airflow, pressure allowance and installation. A higher class should not be substituted without reviewing the complete configuration and operating conditions.

How do I choose between gasket and gel seals?

Match the filter to the housing design. Gasket seals need the specified contact surface and retaining arrangement. Gel-seal filters need a compatible knife-edge interface and channel geometry. These interfaces are not interchangeable simply because the filters have the same face size.

Can I replace a filter with another of the same dimensions?

Check class, sealing method, flange or channel details, airflow direction, operating airflow and pressure drop as well as size. Send the existing filter label and housing photographs or drawings to help review compatibility.

What test documentation should I specify?

Identify the required standard and class, the factory test records you need and any serial-number or traceability requirements. Confirm the documents available for the selected model before ordering. Specify installed-system acceptance requirements separately; do not assume a factory record replaces site testing.

Does a HEPA filter guarantee a cleanroom classification?

No. Filter classification describes the filter, not the complete room. The room classification depends on the overall system, installation, operation and the applicable project verification. Select the filter as part of that complete specification.

Can these filters be washed, and when should they be replaced?

Do not assume these filters can be washed or cleaned for reuse. Follow the supplied product and equipment instructions. Determine replacement using operating pressure drop, airflow, damage or seal condition and applicable project test results. A single replacement interval is not suitable for all installations.

Are all separator filters suitable for high temperatures?

No. Separators alone do not determine the temperature rating. Media, frame, adhesives, seals and installation components must all be compatible with the operating conditions. Confirm continuous and peak temperatures, exposure duration and the supplied configuration.

TELL US WHAT YOU NEED

Specify the Filter Your System Needs

Share the required filter class and test standard, actual dimensions, operating airflow and sealing arrangement. Include the quantity and photos or drawings of the existing filter and housing.

Discuss Your Requirements →

Class & standard · Dimensions · Airflow · Seal type · Quantity · Photos or drawings
Include temperature conditions and documentation requirements where applicable.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top