Paper Separator
HEPA Filters
Fifteen sizes. Three installation depths.
Microglass HEPA media with paper separators in a galvanized steel frame. Choose 150, 220 or 292 mm depth, H13 or H14, and the flange arrangement required by your housing.
- Selected depth
- 150 mm
- Available grades
- H13 / H14
- Frame options
- Galvanized steel
- Filter area
- 3.1–26.6 m²
Built around your
installation requirements.
Paper separator construction
Microfiberglass paper separators support the folds of the microglass filter medium and form airflow channels.
Fifteen dimensional options
Five sizes in 150 mm depth, eight in 220 mm and two in 292 mm cover the listed range. Match the full dimensions to the existing housing.
Three flange arrangements
Single-flange, double-flange and no-flange configurations are available. Specify the mounting interface and sealing arrangement with your enquiry.
Construction & technical parameters
150 mm configuration
- Filter grades
- H13 / H14
- Frame depth
- 150 mm
- Filter medium
- Microglass fibre
- Separators
- Microfiberglass paper
- Frame options
- Galvanized steel
- Recommended final pressure drop
- 600 Pa
- Maximum final pressure drop
- 1000 Pa
- Flange options
- Single flange / double flange / no flange
220 mm configuration
- Filter grades
- H13 / H14
- Frame depth
- 220 mm
- Filter medium
- Microglass fibre
- Separators
- Microfiberglass paper
- Frame options
- Galvanized steel
- Recommended final pressure drop
- 600 Pa
- Maximum final pressure drop
- 1000 Pa
- Flange options
- Single flange / double flange / no flange
292 mm configuration
- Filter grades
- H13 / H14
- Frame depth
- 292 mm
- Filter medium
- Microglass fibre
- Separators
- Microfiberglass paper
- Frame options
- Galvanized steel
- Recommended final pressure drop
- 600 Pa
- Maximum final pressure drop
- 1000 Pa
- Flange options
- Single flange / double flange / no flange
Select your filter
configuration.
Choose a grade and select a row to add the dimensions and filter area to your enquiry.
150 mm · H13
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H13 | 305×305×150 | 320 | 235 | 3.1 | |
| H13 | 305×610×150 | 650 | 235 | 6.4 | |
| H13 | 610×610×150 | 1300 | 235 | 13.2 | |
| H13 | 915×610×150 | 2000 | 235 | 19.9 | |
| H13 | 1220×610×150 | 2600 | 235 | 26.6 |
150 mm · H14
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H14 | 305×305×150 | 320 | 235 | 3.1 | |
| H14 | 305×610×150 | 650 | 235 | 6.4 | |
| H14 | 610×610×150 | 1300 | 235 | 13.2 | |
| H14 | 915×610×150 | 2000 | 235 | 19.9 | |
| H14 | 1220×610×150 | 2600 | 235 | 26.6 |
220 mm · H13
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H13 | 320×320×220 | 450 | 235 | 5.3 | |
| H13 | 484×484×220 | 1300 | 235 | 12.5 | |
| H13 | 726×484×220 | 2000 | 235 | 18.9 | |
| H13 | 968×484×220 | 2600 | 235 | 25.3 | |
| H13 | 315×630×220 | 1000 | 235 | 10.5 | |
| H13 | 630×630×220 | 2000 | 235 | 21.4 | |
| H13 | 945×630×220 | 2900 | 235 | 32.4 | |
| H13 | 1260×630×220 | 4000 | 235 | 43.3 |
220 mm · H14
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H14 | 320×320×220 | 450 | 235 | 5.3 | |
| H14 | 484×484×220 | 1300 | 235 | 12.5 | |
| H14 | 726×484×220 | 2000 | 235 | 18.9 | |
| H14 | 968×484×220 | 2600 | 235 | 25.3 | |
| H14 | 315×630×220 | 1000 | 235 | 10.5 | |
| H14 | 630×630×220 | 2000 | 235 | 21.4 | |
| H14 | 945×630×220 | 2900 | 235 | 32.4 | |
| H14 | 1260×630×220 | 4000 | 235 | 43.3 |
292 mm · H13
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H13 | 305×610×292 | 1300 | 235 | 13.3 | |
| H13 | 610×610×292 | 2700 | 235 | 27.2 |
292 mm · H14
| Grade | W × H × D (mm) | Airflow (m³/h) | Initial pressure drop (Pa) | Filter area (m²) | Select |
|---|---|---|---|---|---|
| H14 | 305×610×292 | 1300 | 235 | 13.3 | |
| H14 | 610×610×292 | 2700 | 235 | 27.2 |
Choose a size below.
Match the housing.
Specify the options.
Dimensions and access
Measure width, height and depth, plus retaining clearance and the route for removing the filter. Provide a housing drawing where available.
Frame and mounting
Galvanized steel frame with single flange, double flange or no flange. Include the housing sealing arrangement with your enquiry.
Operating conditions
Provide the airflow, available pressure, humidity and operating conditions. Match the sealing face and frame material to your installation.
Applications & system integration
Air-handling units
Select dimensions, airflow and pressure drop against the HEPA stage of the air-handling unit.
Existing-system replacements
Compare the existing frame, sealing face and access space with the selected configuration before ordering.
Clean-air supply systems
Use with upstream prefiltration and a housing designed for the required grade and airflow.
Fit correctly. Monitor in service.
Before installation
Check the frame, media and separators for damage. Carry the filter by its frame and verify airflow direction and housing dimensions.
Seat and secure
Keep the sealing surface clean. Apply retaining pressure evenly around the perimeter and match the gasket arrangement to the housing.
Monitor and replace
Record initial pressure drop at operating airflow and monitor the trend. Recommended final pressure drop: 600 Pa. Maximum final pressure drop: 1000 Pa. Replace earlier if the system requires it.
Product questions, answered.
Which depths and grades are available?
150, 220, 292 mm depths are available in H13 and H14. Select a depth to view its sizes and performance values.
Which frame and mounting options can I order?
Galvanized steel frame with single flange, double flange or no flange. Include the housing sealing arrangement with your enquiry.
What do I need to measure?
Provide the full width, height and depth in millimetres, plus the mounting interface, sealing face and available removal space.
How do I specify a replacement?
Select a table row and add the quantity, required frame and operating conditions. Include an existing filter label or housing drawing in your email.
When should the filter be replaced?
Monitor pressure drop and the condition of the filter. The recommended final pressure drop is 600 Pa and the maximum is 1000 Pa; your system may require an earlier change.
Send your size.
Let’s confirm the fit.
Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.