CINRIWA mini-pleat filter series — representative product image
CINRIWA / HEPA & ULPA FILTERS

Mini-pleat
HEPA / ULPA Filters

Four frame depths. One mini-pleat filter range.

Choose the depth and filtration grade to match your installation. Microglass media, protective grids and a one-piece polyurethane gasket form the filter assembly.

Selected depth
30 mm
Available grades
H13 / H14
Frame options
Aluminium
Filter area
1.3–11 m²
CONSTRUCTION & CHOICE

One filter family.
Four installation depths.

Microglass mini-pleat media

Micro fiberglass paper forms the mini-pleat pack. Depth and face size determine the listed filter area for each configuration.

Frame and grid options

The 30 mm model has an aluminium frame. The 69, 78 and 90 mm models offer aluminium or MDF. MDF versions in 69 and 78 mm depths offer single-sided or double-sided grids; the other listed configurations have double-sided grids.

One-piece gasket

A foamed polyurethane gasket forms the sealing surface. Match frame depth, gasket contact and retaining clearance to the housing.

PRODUCT DATA

Construction & technical parameters

Technical data follows your selected frame depth.

30 mm configuration

Filter grades
H13 / H14
Frame depth
30 mm
Filter medium
Micro fiberglass paper
Frame options
Aluminium
Construction
Mini-pleat
Gasket
One-piece foamed polyurethane
Protective grids
Epoxy-painted aluminium grids on both sides
Initial pressure drop
H13: 110 Pa / H14: 120 Pa
Listed airflow
75–600 m³/h
Filter area
1.3–11 m²
Recommended final pressure drop
600 Pa
Maximum final pressure drop
1000 Pa
DEPTH · GRADE · SIZE

Find the configuration
for your installation.

Choose a depth, then a grade. Select a table row to add its dimensions to your enquiry.

30 mm · H13

GradeW × H × D
(mm)
Airflow
(m³/h)
Initial pressure drop
(Pa)
Filter area
(m²)
Select
H13305×305×30751101.3
H13457×457×301701103.1
H13305×610×301501102.8
H13610×610×303001105.5
H13610×762×304001106.8
H13610×914×304501108
H13610×1220×3060011011

30 mm · H13 selected. Choose a size below.

MOUNTING & SEALING

Check the complete installation.

Match the frame depth and sealing face to the housing.

Selected depth
30 mm
Seal
One-piece polyurethane gasket
Mounting check
Perimeter contact and retaining clearance
FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Applications & system integration

Cleanroom terminal supply

Use within a clean-air system designed for the required filtration grade. Match the filter dimensions and mounting interface to the terminal housing.

Compatible FFUs and clean-air equipment

Check the unit depth, airflow requirements, pressure allowance and gasket contact against the equipment design.

Local clean-air work zones

Provide the required grade and installation details for equipment-integrated filter sections and local clean-air enclosures.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Confirm the frame dimensions, gasket condition and airflow direction. Carry the filter by its frame without pressing the media.

02 / SEAL

Seat & secure

Apply retaining pressure evenly around the frame. Keep the housing contact surface clean and check for gaps around the perimeter.

03 / MONITOR

Track condition

Record pressure drop under the operating conditions. Inspect the frame, protective grids and gasket during maintenance.

04 / REPLACE

Follow system limits

Plan replacement against the system requirements and pressure-drop trend. Replace damaged filters rather than washing or blowing out the media.

BEFORE YOU ORDER

Product questions, answered.

Which grades can I choose?

30 and 90 mm models are available in H13 and H14. The 69 and 78 mm models also offer U15.

Do all depths have the same sizes?

No. The 30, 69 and 78 mm models each list seven face sizes. The 90 mm model lists five. Use the specification table for the selected depth.

Which frames and protective grids are available?

30 mm uses an aluminium frame with double-sided grids. The other depths offer aluminium or MDF frames. MDF versions in 69 and 78 mm depths can have single-sided or double-sided grids; 90 mm versions have double-sided grids.

How do I choose the installation depth?

Measure the housing slot and gasket contact surface. Check retaining clearance and the required filtration grade before selecting a listed size.

What are the final pressure-drop values?

Recommended final pressure drop is 600 Pa; maximum final pressure drop is 1000 Pa. Plan replacement against the operating requirements of your system.

What should I send for a quotation?

Select the depth, grade and size, then add quantity, frame preference, operating airflow and mounting details. Include photos or drawings in your email where available.

MINI-PLEAT HEPA / ULPA FILTERS

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top