Pleated Primary Panel Filter
CINRIWA / PRE-FILTERS

Pleated Primary
Panel Filter

Pleated polyester media for fresh air, return air and industrial ventilation.

Choose G3 or G4, 45 or 95 mm depth, and one of six face sizes. The pleated medium captures coarse dust and fibres ahead of coils and subsequent filtration stages.

Filter class
EN 779 G3 / G4
Depth options
45 / 95 mm
Medium
Polyester synthetic fibre
Frame options
Metal / plastic
CONSTRUCTION & CHOICE

Choose the grade.
Find the right fit.

G3 & G4 options

Two filter grades are available in each depth and face size. Select the grade required by your ventilation system.

Two installation depths

45 mm and 95 mm options accommodate different mounting spaces. Media areas range from 0.2–0.8 m² at 45 mm and 0.4–1.6 m² at 95 mm.

Metal or plastic frames

Choose the frame to match the mounting arrangement and operating environment. Six face sizes include 287 × 287 mm and 592 × 287 mm modules.

PRODUCT DATA

Materials & operating parameters

Filter medium
Polyester synthetic fibre
Frame options
Metal / plastic
Filter grades
EN 779 G3 / G4
Depth options
45 / 95 mm
Listed configurations
24
Face sizes
6
Final pressure drop
250 Pa
Maximum operating temperature
80°C
SIZE SELECTOR

Find your dimensions.
Check your airflow.

Compare six sizes in each grade and depth. Airflow and resistance are listed together at three face velocities.

G3 · 45 mm

GradeW × H × D
(mm)
Media area
(m²)
1.5 m/s
Airflow (m³/h)
1.5 m/s
Resistance (Pa)
2.5 m/s
Airflow (m³/h)
2.5 m/s
Resistance (Pa)
3.2 m/s
Airflow (m³/h)
3.2 m/s
Resistance (Pa)
G3287×287×450.25003085045100055
G3500×500×450.6150030240045300055
G3500×625×450.7180030240045370055
G3592×287×450.4100030175045210055
G3592×490×450.6170030240045350055
G3592×592×450.8200030340045420055

Please confirm filter dimensions and operating airflow before ordering.

Width (W)Height (H)Depth (D)

Dimension guide · schematic, not a manufacturing drawing

FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Prefiltration for compatible air systems

Fresh & return air

Coarse-dust and fibre capture in commercial air conditioning and industrial ventilation, ahead of subsequent filtration stages.

Modular air-handling units

Small, half-width and full-width modules support different filter-bank arrangements. Seal the joints between adjacent filters.

Equipment intake & retrofit

Match the existing opening, available depth and airflow. Confirm the frame material and grade before replacing the filter.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Confirm dimensions, depth, frame material and airflow direction before installation. Avoid bending the frame or forcing the filter into the opening.

02 / SEAL

Seat & secure

Apply even retaining pressure and check continuous sealing around the frame. Inspect joints between adjacent filters for bypass gaps.

03 / MONITOR

Track condition

Record the initial pressure drop and compare readings at the same airflow. Inspect media, frame and seals during routine maintenance.

04 / REPLACE

Follow system limits

Replace the filter according to pressure-drop monitoring and equipment maintenance requirements.

BEFORE YOU ORDER

Product questions, answered.

Which grades and depths are available?

G3 and G4 are each available in 45 and 95 mm depths, with six face sizes per combination.

How do I choose between 45 and 95 mm?

Check the available mounting depth, then compare the media area, airflow and resistance for the selected grade and size.

Which frame materials can I order?

Metal and plastic frames are available. Include your preferred frame and installation requirements with the enquiry.

What information is needed for a quotation?

Send the required dimensions, grade, depth, frame preference, operating airflow and quantity.

When should the filter be replaced?

Monitor pressure drop and filter condition. The listed final pressure drop is 250 Pa; follow your equipment maintenance requirements.

PLEATED PRIMARY PANEL FILTER

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top