High Temperature Filter Panel
CINRIWA / PRE-FILTERS

High Temperature
Filter Panel

Framed glass-fibre filtration for hot-air systems and drying equipment.

Long-filament glass fibre is supported by a retaining mesh, outer frame and downstream support bars. Choose 20 or 46 mm depth, with flat or corrugated media construction.

Temperature resistance
250°C
Depth options
20 / 46 mm
Medium
Long-filament glass fibre
Frame options
Aluminium alloy / galvanized steel
CONSTRUCTION & CHOICE

Supported media.
A framed solution for hot air.

Framed panel assembly

A formed filter panel combines glass-fibre media, retaining mesh and an outer frame for installation in a compatible filter section.

Supported filter medium

The retaining mesh and downstream support bars help hold the medium in position and support it against airflow.

Two media constructions

Flat and corrugated media options are available with aluminium alloy or galvanized steel frames. The listed specifications apply to both constructions and frame options.

PRODUCT DATA

Materials & operating parameters

Filter medium
Long-filament glass fibre
Frame options
Aluminium alloy / galvanized steel
Media construction
Flat / corrugated
Media support
Retaining mesh and downstream support bars
Listed sizes
500 × 500 × 20 / 46 mm
Initial resistance
20 Pa
Final pressure drop
200 Pa
Temperature resistance
250°C
Dust-holding capacity
20 mm: 80 g/m² · 46 mm: 120 g/m²
Specification coverage
Both constructions and both frame options
SIZE SELECTOR

Find your size.
Compare the specifications.

Compare the 20 and 46 mm models. Specifications apply to both flat and corrugated constructions, with either frame material.

20 mm

W × H × D
(mm)
Initial resistance
(Pa)
Final pressure drop
(Pa)
Dust-holding capacity
(g/m²)
Temperature resistance
(°C)
500×500×202020080250

Please confirm filter dimensions and operating conditions before ordering.

Width (W)Height (H)Depth (D)

Dimension guide · schematic, not a manufacturing drawing

FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Prefiltration for compatible air systems

Drying & curing equipment

Prefiltration in compatible hot-air drying and curing systems. Select the panel and installation components to suit the process conditions.

Hot-air supply & recirculation

Particle prefiltration for hot-air supply and circulating-air systems, including suitable coating-line and oven installations.

Equipment replacement

A framed panel for replacement in existing filter sections. Confirm mounting dimensions, temperature conditions and allowable pressure drop.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Check the panel dimensions, frame and media. Install with the support bars on the downstream side and follow the airflow direction.

02 / SEAL

Seat & secure

Use mounting hardware and sealing materials suitable for the operating temperature. Apply even pressure around the frame.

03 / MONITOR

Track condition

Monitor pressure drop and inspect the mesh, media and frame. The listed final pressure drop is 200 Pa.

04 / REPLACE

Follow system limits

Shut down and allow the equipment to cool before removal. Follow the equipment isolation and maintenance procedures.

BEFORE YOU ORDER

Product questions, answered.

Which sizes are listed?

500 × 500 × 20 mm and 500 × 500 × 46 mm are listed.

Which frames and constructions are available?

Aluminium alloy and galvanized steel frames are available with flat or corrugated media. The specification table applies to all these options.

What temperature resistance is listed?

The listed temperature resistance is 250°C. Include the operating temperature and process conditions in your enquiry so the complete installation can be reviewed.

How does dust-holding capacity differ?

The listed dust-holding capacity is 80 g/m² at 20 mm depth and 120 g/m² at 46 mm depth.

What should I specify when ordering?

Send dimensions, depth, frame material, media construction, operating temperature, airflow and quantity. Include installation drawings where available.

HIGH TEMPERATURE FILTER PANEL

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top