Cardboard framed pleated synthetic fibre panel filters
CINRIWA / PRE-FILTERS

Cardboard Pleated
Panel Filter

Synthetic fibre prefiltration in a lightweight, replaceable cardboard frame.

For compatible ventilation and air-handling systems, this pleated panel captures coarse airborne dust and fibres upstream of subsequent filtration stages.

Filter class
EN 779 G4*
Depth options
25 / 51 / 102 mm
Medium
Synthetic fibre
Construction
Disposable paper frame
CONSTRUCTION & CHOICE

A practical first stage.
A configuration that fits.

Choose the filter by installation fit, operating conditions and required performance—not by dimensions alone.

Pleated synthetic media

The folded medium provides an expanded filtration surface within a panel format. Choose a size that matches your equipment and operating requirements.

Whole-filter replacement

A framed assembly can be replaced as a complete unit in a compatible mounting system. Check retaining hardware and seals whenever a filter is changed.

Three depth options

Choose from 25, 51 and 102 mm depths. Confirm the mounting dimensions, operating airflow and equipment requirements before ordering.

PRODUCT DATA

Materials & operating parameters

Frame
Cardboard
Filter medium
Non-woven / synthetic fibre composite
Construction
Pleated panel
Depth options
25 / 51 / 102 mm
Catalogue filter class
EN 779 G4
Catalogue average arrestance
90–92%
Catalogue final pressure drop
250 Pa
Catalogue maximum operating temperature
80°C

*Class and performance figures are catalogue-listed values. Arrestance is a dust-weight capture measure, not a stated efficiency for every particle size. Confirm the applicable specification and test basis for your order.

SIZE SELECTOR

Find your dimensions.
Check your airflow.

Select a depth to view its listed sizes and airflow. FPM describes face velocity; CFM describes airflow.

Dimensions & airflow

Airflow in CFM at the stated face velocity in FPM. Dimensions shown in millimetres; confirm fit before ordering.

Nominal size
(inches)
Listed dimensions
W × H × D (mm)
300 FPM
CFM
500 FPM
CFM
625 FPM
CFM
12x24x1305 × 610 × 256001000—
16x20x1406 × 508 × 256501100—
16x25x1406 × 635 × 258501400—
20x20x1508 × 508 × 258501400—
20x25x1508 × 635 × 2510501750—
24x24x1610 × 610 × 2512002000—

Please confirm filter dimensions and operating airflow before ordering.

Width (W)Height (H)Depth (D)

Dimension guide · schematic, not a manufacturing drawing

FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Prefiltration for compatible air systems

HVAC & ventilation

First-stage filtration in suitable air-conditioning and ventilation equipment, ahead of downstream filters.

Return-air filtration

Selected return-air installations where the dust type, environment and equipment requirements suit this construction.

Equipment prefiltration

Compatible air-compressor intake and local high-efficiency filtration equipment, subject to the equipment manufacturer's requirements.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Confirm size, frame integrity and required airflow direction. Avoid bending or forcing the cardboard frame into the slot.

02 / SEAL

Seat & secure

Check continuous contact with the mounting frame and secure the filter as required. Inspect corners and joins for bypass gaps.

03 / MONITOR

Track condition

Where monitoring is available, compare pressure drop at the same airflow. Inspect for frame deformation, media damage and leakage.

04 / REPLACE

Follow system limits

Replace the filter according to pressure-drop monitoring and equipment maintenance requirements.

BEFORE YOU ORDER

Product questions, answered.

Can this filter be washed and reused?

This is a disposable replacement filter, not a washable product. If your installation requires cleaning and reuse, ask us about an alternative construction.

Are nominal inch sizes the actual installation dimensions?

Do not select a replacement by the inch designation alone. Confirm the listed millimetre dimensions against the existing filter and mounting slot before placing an order.

Can I use this filter in damp conditions?

Where persistent humidity, condensation or liquid contact is expected, confirm frame and media suitability before ordering. A dimensional match alone does not establish suitability.

When should the filter be replaced?

Use the equipment requirements, pressure-drop trend, airflow and filter condition to set the maintenance interval. The catalogue lists 250 Pa as the final pressure drop; your equipment may require replacement earlier.

Can you supply a non-standard size?

Send the required dimensions or a drawing. Available dimensions, construction and order requirements will be confirmed with the quotation.

CARDBOARD PLEATED PANEL FILTER

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top