Pre Filter — Ambient Temperature
CINRIWA / PRE-FILTERS

Pre Filter
Ambient Temperature

Synthetic fibre prefiltration with a choice of metal frames and three constructions.

A panel pre-filter for ambient-temperature ventilation systems. Select from four listed sizes, with flat, pleated or inner-and-outer frame construction to suit your installation.

Application
Ambient-temperature prefiltration
Depth options
45 / 90 mm
Medium
Flame-retardant synthetic fibre
Constructions
Flat / pleated / inner-and-outer frame
CONSTRUCTION & CHOICE

Choose your frame.
Match your installation.

Three constructions

Choose flat, pleated or inner-and-outer frame construction. The specification table applies to all three options.

Three metal frame options

Galvanized steel, aluminium alloy and stainless steel frames are available. Specify the frame material when requesting a quotation.

Four listed sizes

Choose 595 × 595 or 290 × 595 mm face dimensions, in 45 or 90 mm depth. Initial resistance is ≤50 Pa at 45 mm and ≤75 Pa at 90 mm at the listed rated airflow.

PRODUCT DATA

Materials & operating parameters

Filter medium
Flame-retardant synthetic fibre
Frame options
Galvanized steel / aluminium alloy / stainless steel
Constructions
Flat / pleated / inner-and-outer frame
Depth options
45 / 90 mm
Listed sizes
4
Rated airflow
1700 / 3400 m³/h
Initial resistance
45 mm: ≤50 Pa · 90 mm: ≤75 Pa
Recommended final pressure drop
45 mm: 220–230 Pa · 90 mm: 230–240 Pa
Filter area by face size
595 × 595 mm: 1.96 m² · 290 × 595 mm: 1 m²
Operating application
Ambient-temperature ventilation
SIZE SELECTOR

Find your dimensions.
Check your airflow.

Compare the four listed sizes. These specifications apply to flat, pleated and inner-and-outer frame constructions. Filter area is the same at both depths for each face size.

45 mm

W × H × D
(mm)
Rated airflow
(m³/h)
Initial resistance
(Pa)
Recommended final
resistance (Pa)
Filter area
(m²)
595×595×453400≤50220–2301.96
290×595×451700≤50220–2301

Please confirm filter dimensions and operating airflow before ordering.

Width (W)Height (H)Depth (D)

Dimension guide · schematic, not a manufacturing drawing

FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Prefiltration for compatible air systems

HVAC prefiltration

Use in fresh-air and return-air systems to capture coarse dust and fibres upstream of coils and subsequent filters.

Compressor intake prefiltration

Provide a coarse prefiltration stage for compatible large air-compressor intake systems. Match the number of filters to the required airflow.

Cleanroom return & HEPA prefiltration

Use as an upstream pre-filter or return-air filter. Select downstream filtration to meet the system’s air-quality requirements.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Confirm dimensions, depth, frame material and airflow direction before installation. Avoid bending the frame or forcing the filter into the opening.

02 / SEAL

Seat & secure

Apply even retaining pressure and check continuous sealing around the frame. Inspect joints between adjacent filters for bypass gaps.

03 / MONITOR

Track condition

Record the initial pressure drop and compare readings at the same airflow. Inspect media, frame and seals during routine maintenance.

04 / REPLACE

Follow system limits

Replace the filter according to pressure-drop monitoring and equipment maintenance requirements.

BEFORE YOU ORDER

Product questions, answered.

Which constructions are available?

Flat, pleated and inner-and-outer frame constructions are available. The four-size specification table applies to all three.

Does the filter area change with depth?

For each face size, the listed filter area is the same at 45 and 90 mm depth: 1.96 m² for 595 × 595 mm and 1 m² for 290 × 595 mm.

Which frame materials are available?

Choose galvanized steel, aluminium alloy or stainless steel. Specify the required material and construction in your enquiry.

What is the recommended final pressure drop?

The recommended range is 220–230 Pa for 45 mm models and 230–240 Pa for 90 mm models. Plan replacement using pressure-drop monitoring and equipment maintenance requirements.

What information should I send for a quotation?

Send the required size, depth, frame material, construction, airflow and quantity. Include the operating temperature and installation details.

PRE FILTER — AMBIENT TEMPERATURE

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top