Flanged Aluminium Separator Filter
High Temperature
Microglass media and corrugated aluminium separators in a galvanized steel frame.
Available in F6, F7 and F8, with a temperature resistance of 350°C. Choose 150 or 292 mm depth with single-flange, double-flange or no-flange construction.
- Filter grades
- F6 / F7 / F8
- Temperature resistance
- 350°C
- Filter medium
- Micro fiberglass paper
- Frame
- Galvanized steel
Metal separators.
Three mounting options.
Aluminium foil separators
Corrugated aluminium foil separates the microglass pleats. The outer frame is galvanized steel.
Three mounting options
Single-flange, double-flange and no-flange configurations share the listed specifications. Confirm the interface dimensions against your housing.
Two depths for selection
150 and 292 mm models have different rated airflow and media area. Compare the complete model row for your required grade.
Materials & operating parameters
- Filter grades
- F6 / F7 / F8
- Temperature resistance
- 350°C
- Filter medium
- Micro fiberglass paper
- Frame
- Galvanized steel
- Separators
- Corrugated aluminium foil
- Mounting options
- Single flange / double flange / no flange
- Depth options
- 150 / 292 mm
- Rated airflow
- 850–3400 m³/h, by model
- Initial resistance
- 40–150 Pa, by model
- Filter area
- 3–11 m²
- Recommended final pressure drop
- 450 Pa
- Maximum final pressure drop
- 600 Pa
Choose a grade.
Review the data.
Select a grade to view the listed dimensions, rated airflow, initial resistance and filter area.
F6
| Grade | W × H × D (mm) | Rated airflow (m³/h) | Initial resistance (Pa) | Filter area (m²) |
|---|---|---|---|---|
| F6 | 287×592×150 | 850 | 40 | 3 |
| F6 | 490×592×150 | 1400 | 40 | 5 |
| F6 | 592×592×150 | 1800 | 40 | 6 |
| F6 | 287×592×292 | 1800 | 100 | 6 |
| F6 | 490×592×292 | 2750 | 100 | 10 |
| F6 | 592×592×292 | 3400 | 100 | 11 |
F7
| Grade | W × H × D (mm) | Rated airflow (m³/h) | Initial resistance (Pa) | Filter area (m²) |
|---|---|---|---|---|
| F7 | 287×592×150 | 850 | 75 | 3 |
| F7 | 490×592×150 | 1400 | 75 | 5 |
| F7 | 592×592×150 | 1800 | 75 | 6 |
| F7 | 287×592×292 | 1800 | 140 | 6 |
| F7 | 490×592×292 | 2750 | 140 | 10 |
| F7 | 592×592×292 | 3400 | 140 | 11 |
F8
| Grade | W × H × D (mm) | Rated airflow (m³/h) | Initial resistance (Pa) | Filter area (m²) |
|---|---|---|---|---|
| F8 | 287×592×150 | 850 | 85 | 3 |
| F8 | 490×592×150 | 1400 | 85 | 5 |
| F8 | 592×592×150 | 1800 | 85 | 6 |
| F8 | 287×592×292 | 1800 | 150 | 6 |
| F8 | 490×592×292 | 2750 | 150 | 10 |
| F8 | 592×592×292 | 3400 | 150 | 11 |
Please confirm filter dimensions and operating airflow before ordering.
Confirm the mounting fit.
Match the filter to the housing and retaining arrangement.
- Mounting check
- Face dimensions, depth and seal contact
- Before ordering
- Send a drawing or an existing-filter photo
Measure the installation.
Confirm the filter.
Measure the existing filter and mounting slot. Include clearances, seals and retaining details.
Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.
Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.
Applications & system integration
Hot-air process systems
Particle filtration where the process specification calls for a high-temperature filter. Confirm the operating temperature profile.
Drying and heated ventilation
Review the filter grade, airflow and mounting interface for the heated-air section.
Multi-stage process filtration
Use with appropriate upstream filtration and confirm that housing seals and retaining parts suit the operating conditions.
Fit correctly. Monitor in service.
Before installation
Check dimensions and mounting fit. Follow the airflow arrow and handle the filter by its frame, keeping pressure off the media.
Seat & secure
Confirm the housing seals and retaining components suit the operating temperature. Apply even pressure around the sealing face.
Track condition
Record initial pressure drop at the operating airflow. Inspect the frame, filter pack and seals during maintenance.
Follow system limits
Plan replacement using pressure-drop monitoring and equipment maintenance requirements. Replace damaged filters promptly.
Product questions, answered.
Does aluminium refer to the outer frame?
It refers to the corrugated separators. The outer frame is galvanized steel.
Do the mounting options share these specifications?
Yes. Single-flange, double-flange and no-flange versions share the listed data. Confirm interface dimensions before ordering.
How are the two final pressure-drop values listed?
Recommended final pressure drop is 450 Pa. Maximum final pressure drop is 600 Pa.
What is the temperature resistance?
Temperature resistance is 350°C. Include operating temperature and installation details in your enquiry.
What information is needed for a quotation?
Send your required grade, dimensions, quantity, operating airflow and installation details. Include drawings or photos of the housing where available.
Send your size.
Let’s confirm the fit.
Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.
Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.