Choose M6, F7, F8 or F9. Each grade has a rated airflow of 3000 m³/h, with grade-specific initial resistance and dust-holding capacity.

Filter grades
M6 / F7 / F8 / F9
Rated airflow
3000 m³/h
Maximum recommended airflow
3750 m³/h
Construction
Deep-pleated cassette
CONSTRUCTION & CHOICE

A clear view of
cassette performance.

Deep-pleated construction

Thermo-embossed media forms the deep pleats within the cassette filter element.

Two airflow values

Rated airflow is 3000 m³/h. Maximum recommended airflow is 3750 m³/h; these are shown separately for selection.

Grade-specific performance

Compare initial pressure drop and dust-holding capacity for M6, F7, F8 and F9 alongside the required filtration grade.

PRODUCT DATA

Materials & operating parameters

Filter grades
M6 / F7 / F8 / F9
Rated airflow
3000 m³/h
Maximum recommended airflow
3750 m³/h
Construction
Deep-pleated cassette
Mounting options
Single flange / no flange
Initial resistance
135 / 140 / 150 / 175 Pa, by grade
Dust-holding capacity
1500–2300 g, by grade
Recommended final pressure drop
650 Pa
GRADE & SPECIFICATIONS

Choose a grade.
Review the data.

Compare rated airflow, maximum recommended airflow, initial resistance and dust-holding capacity.

M6

GradeRated airflow
(m³/h)
Maximum recommended
airflow (m³/h)
Initial resistance
(Pa)
Recommended final
pressure drop (Pa)
Dust-holding
capacity (g)
M6300037501356502300

Please confirm filter dimensions and operating airflow before ordering.

INSTALLATION CHECK

Confirm the mounting fit.

Match the filter to the housing and retaining arrangement.

Mounting check
Face dimensions, depth and seal contact
Before ordering
Send a drawing or an existing-filter photo
FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Applications & system integration

Engine and turbine air intake

Review the filter dimensions, mounting interface and operating requirements against the equipment specification.

Industrial process air

Particle filtration for compatible industrial air-handling systems, with grade selected to suit the process requirements.

HVAC and recirculation

Cassette filtration in compatible air intake, exhaust and recirculation systems.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Check dimensions and mounting fit. Follow the airflow arrow and handle the filter by its frame, keeping pressure off the media.

02 / SEAL

Seat & secure

Apply even retaining pressure. Check the perimeter seal and filter-bank joints for bypass gaps.

03 / MONITOR

Track condition

Record initial pressure drop at the operating airflow. Inspect the frame, filter pack and seals during maintenance.

04 / REPLACE

Follow system limits

Plan replacement using pressure-drop monitoring and equipment maintenance requirements. Replace damaged filters promptly.

BEFORE YOU ORDER

Product questions, answered.

Which grades are available?

M6, F7, F8 and F9 are listed. Select the grade required by your system specification.

What is the difference between the two airflow values?

3000 m³/h is the rated airflow; 3750 m³/h is the maximum recommended airflow.

What should I send to confirm fit?

Send dimensions, a drawing or photos of the existing filter and housing, the mounting arrangement, required grade and operating airflow.

What information is needed for a quotation?

Send your required grade, dimensions, quantity, operating airflow and installation details. Include drawings or photos of the housing where available.

CASSETTE FILTER

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top