Paper Separator HEPA Filters
CINRIWA / HEPA & ULPA FILTERS

Paper Separator
HEPA Filters

Fifteen sizes. Three installation depths.

Microglass HEPA media with paper separators in a galvanized steel frame. Choose 150, 220 or 292 mm depth, H13 or H14, and the flange arrangement required by your housing.

Selected depth
150 mm
Available grades
H13 / H14
Frame options
Galvanized steel
Filter area
3.1–26.6 m²
CONSTRUCTION & CHOICE

Built around your
installation requirements.

Paper separator construction

Microfiberglass paper separators support the folds of the microglass filter medium and form airflow channels.

Fifteen dimensional options

Five sizes in 150 mm depth, eight in 220 mm and two in 292 mm cover the listed range. Match the full dimensions to the existing housing.

Three flange arrangements

Single-flange, double-flange and no-flange configurations are available. Specify the mounting interface and sealing arrangement with your enquiry.

PRODUCT DATA

Construction & technical parameters

150 mm configuration

Filter grades
H13 / H14
Frame depth
150 mm
Filter medium
Microglass fibre
Separators
Microfiberglass paper
Frame options
Galvanized steel
Recommended final pressure drop
600 Pa
Maximum final pressure drop
1000 Pa
Flange options
Single flange / double flange / no flange
DEPTH · GRADE · SIZE

Select your filter
configuration.

Choose a grade and select a row to add the dimensions and filter area to your enquiry.

150 mm · H13

GradeW × H × D
(mm)
Airflow
(m³/h)
Initial pressure drop
(Pa)
Filter area
(m²)
Select
H13305×305×1503202353.1
H13305×610×1506502356.4
H13610×610×150130023513.2
H13915×610×150200023519.9
H131220×610×150260023526.6

Choose a size below.

FIT & CONFIGURATION

Match the housing.
Specify the options.

Dimensions and access

Measure width, height and depth, plus retaining clearance and the route for removing the filter. Provide a housing drawing where available.

Frame and mounting

Galvanized steel frame with single flange, double flange or no flange. Include the housing sealing arrangement with your enquiry.

Operating conditions

Provide the airflow, available pressure, humidity and operating conditions. Match the sealing face and frame material to your installation.

APPLICATIONS

Applications & system integration

Air-handling units

Select dimensions, airflow and pressure drop against the HEPA stage of the air-handling unit.

Existing-system replacements

Compare the existing frame, sealing face and access space with the selected configuration before ordering.

Clean-air supply systems

Use with upstream prefiltration and a housing designed for the required grade and airflow.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

Before installation

Check the frame, media and separators for damage. Carry the filter by its frame and verify airflow direction and housing dimensions.

Seat and secure

Keep the sealing surface clean. Apply retaining pressure evenly around the perimeter and match the gasket arrangement to the housing.

Monitor and replace

Record initial pressure drop at operating airflow and monitor the trend. Recommended final pressure drop: 600 Pa. Maximum final pressure drop: 1000 Pa. Replace earlier if the system requires it.

BEFORE YOU ORDER

Product questions, answered.

Which depths and grades are available?

150, 220, 292 mm depths are available in H13 and H14. Select a depth to view its sizes and performance values.

Which frame and mounting options can I order?

Galvanized steel frame with single flange, double flange or no flange. Include the housing sealing arrangement with your enquiry.

What do I need to measure?

Provide the full width, height and depth in millimetres, plus the mounting interface, sealing face and available removal space.

How do I specify a replacement?

Select a table row and add the quantity, required frame and operating conditions. Include an existing filter label or housing drawing in your email.

When should the filter be replaced?

Monitor pressure drop and the condition of the filter. The recommended final pressure drop is 600 Pa and the maximum is 1000 Pa; your system may require an earlier change.

PAPER SEPARATOR HEPA FILTERS

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top