Flanged Aluminium Separator Filter
CINRIWA / FINE AIR FILTERS

Flanged Aluminium Separator Filter
High Temperature

Microglass media and corrugated aluminium separators in a galvanized steel frame.

Available in F6, F7 and F8, with a temperature resistance of 350°C. Choose 150 or 292 mm depth with single-flange, double-flange or no-flange construction.

Filter grades
F6 / F7 / F8
Temperature resistance
350°C
Filter medium
Micro fiberglass paper
Frame
Galvanized steel
CONSTRUCTION & CHOICE

Metal separators.
Three mounting options.

Aluminium foil separators

Corrugated aluminium foil separates the microglass pleats. The outer frame is galvanized steel.

Three mounting options

Single-flange, double-flange and no-flange configurations share the listed specifications. Confirm the interface dimensions against your housing.

Two depths for selection

150 and 292 mm models have different rated airflow and media area. Compare the complete model row for your required grade.

PRODUCT DATA

Materials & operating parameters

Filter grades
F6 / F7 / F8
Temperature resistance
350°C
Filter medium
Micro fiberglass paper
Frame
Galvanized steel
Separators
Corrugated aluminium foil
Mounting options
Single flange / double flange / no flange
Depth options
150 / 292 mm
Rated airflow
850–3400 m³/h, by model
Initial resistance
40–150 Pa, by model
Filter area
3–11 m²
Recommended final pressure drop
450 Pa
Maximum final pressure drop
600 Pa
GRADE & SPECIFICATIONS

Choose a grade.
Review the data.

Select a grade to view the listed dimensions, rated airflow, initial resistance and filter area.

F6

GradeW × H × D
(mm)
Rated airflow
(m³/h)
Initial resistance
(Pa)
Filter area
(m²)
F6287×592×150850403
F6490×592×1501400405
F6592×592×1501800406
F6287×592×29218001006
F6490×592×292275010010
F6592×592×292340010011

Please confirm filter dimensions and operating airflow before ordering.

INSTALLATION CHECK

Confirm the mounting fit.

Match the filter to the housing and retaining arrangement.

Mounting check
Face dimensions, depth and seal contact
Before ordering
Send a drawing or an existing-filter photo
FIT & CUSTOM REQUIREMENTS

Measure the installation.
Confirm the filter.

01
Width × height × depth

Measure the existing filter and mounting slot. Include clearances, seals and retaining details.

02
Airflow & environment

Provide airflow, allowable pressure drop, temperature and any humidity or liquid exposure.

03
Quantity & configuration

Share the quantity, required specification and photos or drawings. Non-standard dimensions are reviewed before quotation.

Discuss your requirements →
APPLICATIONS

Applications & system integration

Hot-air process systems

Particle filtration where the process specification calls for a high-temperature filter. Confirm the operating temperature profile.

Drying and heated ventilation

Review the filter grade, airflow and mounting interface for the heated-air section.

Multi-stage process filtration

Use with appropriate upstream filtration and confirm that housing seals and retaining parts suit the operating conditions.

INSTALLATION & MAINTENANCE

Fit correctly. Monitor in service.

01 / CHECK

Before installation

Check dimensions and mounting fit. Follow the airflow arrow and handle the filter by its frame, keeping pressure off the media.

02 / SEAL

Seat & secure

Confirm the housing seals and retaining components suit the operating temperature. Apply even pressure around the sealing face.

03 / MONITOR

Track condition

Record initial pressure drop at the operating airflow. Inspect the frame, filter pack and seals during maintenance.

04 / REPLACE

Follow system limits

Plan replacement using pressure-drop monitoring and equipment maintenance requirements. Replace damaged filters promptly.

BEFORE YOU ORDER

Product questions, answered.

Does aluminium refer to the outer frame?

It refers to the corrugated separators. The outer frame is galvanized steel.

Do the mounting options share these specifications?

Yes. Single-flange, double-flange and no-flange versions share the listed data. Confirm interface dimensions before ordering.

How are the two final pressure-drop values listed?

Recommended final pressure drop is 450 Pa. Maximum final pressure drop is 600 Pa.

What is the temperature resistance?

Temperature resistance is 350°C. Include operating temperature and installation details in your enquiry.

What information is needed for a quotation?

Send your required grade, dimensions, quantity, operating airflow and installation details. Include drawings or photos of the housing where available.

FLANGED ALUMINIUM SEPARATOR FILTER

Send your size.
Let’s confirm the fit.

Tell us the dimensions, quantity and operating requirements. Include photos or drawings in your email so we can review the configuration.

Use our contact page →

sales@filtros-cinriwa.com

Prefer email? Fill in the short brief to prepare a message in your email app. Add any files before sending.

Opens your email app. Nothing is sent automatically.

CINRIWA · PRODUCT SUPPORT

Send Your Inquiry

Tell us what you need. Simon and our team will help review the right configuration.

PDF, JPG or PNG · up to 3 files · 10 MB each, 15 MB total

We use these details to respond to your inquiry. Attachments are available only to our authorised team.

Prefer a conversation? Chat on WhatsApp ↗
Scroll to Top